Low Voltage Distribution & Motor Control Systems

Low Voltage Distribution & Motor Control Systems Designing of Low Voltage Panels.

Preparing of BOQ/Estimation
Fault Troubleshooting
Programming of PLC (Siemens & Schneider)
VFD/Soft Starter Programming (Schneider, ABB, Invertek)

Condenser pump Panel  for Phoenix Industries Ltd.PID Control Presssure Booster System for Condenser Pump.4-20mA Pressure...
14/08/2018

Condenser pump Panel for Phoenix Industries Ltd.

PID Control Presssure Booster System for Condenser Pump.

4-20mA Pressure Signal is fed as PID controller of ABB ACS355 VFD to control the rpm of the pump according to set pressure.

1Duty 1Asisst operation ensures reliable pressure while ensuring the energy savings of the system in Variable torque app...
05/08/2018

1Duty 1Asisst operation ensures reliable pressure while ensuring the energy savings of the system in Variable torque applications.
System is installed at Clive Garden Hotel - Wadduwa.

PLC operaed 1-Duty 1-Assist 1Standby DOL Pump Control Panel for Sewerage Pump Pit 2 (Hikkaduwa)at NWS&DB - RSC, Southern...
05/08/2018

PLC operaed 1-Duty 1-Assist 1Standby DOL Pump Control Panel for Sewerage Pump Pit 2 (Hikkaduwa)at NWS&DB - RSC, Southern.

All the standard protections are included as shown in pictures.

Pumps operation is depended upon the water level detected by 3 Nos of Level Regulators( Float switches).

Pumps are alternating during operation to ensure equal running hours.

If one pump istripped during operation, system will automatically swittches on the next pump and once the fault is cleared, relevant pump will turned on switching off the standby pump.

This panel is with dedicated VFD for each pump. Schneder ATV312 VFDs are used with ATV71 HMI mounted in fron door for co...
04/08/2018

This panel is with dedicated VFD for each pump. Schneder ATV312 VFDs are used with ATV71 HMI mounted in fron door for control and data display. Flygt Submerssible pumps are controlled via panel. Water is acquired from the pumps mounted in pontoon submerged in the river shown.

7.5kw 1Duty 1Standby VFD operated Pump Panel Panel SL-Army Hosuing Complex- Manning Town Narahenpita
04/08/2018

7.5kw 1Duty 1Standby VFD operated Pump Panel Panel SL-Army Hosuing Complex- Manning Town Narahenpita

Programming a Logo PLC.
04/08/2018

Programming a Logo PLC.

MagFlux flow meter Installation and commissioning at Thuruwila & Wijepura Water intake and Water Tower.
04/08/2018

MagFlux flow meter Installation and commissioning at Thuruwila & Wijepura Water intake and Water Tower.

This is enegy saving VFD operated Pressure Booster Pump Control Panel designed to Ceylon Biscuits Limited - Ranala.
04/08/2018

This is enegy saving VFD operated Pressure Booster Pump Control Panel designed to Ceylon Biscuits Limited - Ranala.

Portable 4kW DOL 1Duty Pump Control Panel
04/08/2018

Portable 4kW DOL 1Duty Pump Control Panel